pin spotter biorobotics microgrid ii Search Results


90
BioRobotics Ltd pin spotter microgrid 2
Pin Spotter Microgrid 2, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pin spotter microgrid 2/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
pin spotter microgrid 2 - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd pin spotter biorobotics microgrid ii
Pin Spotter Biorobotics Microgrid Ii, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pin spotter biorobotics microgrid ii/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
pin spotter biorobotics microgrid ii - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd microgrid ii mgii 600 robot
Microgrid Ii Mgii 600 Robot, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microgrid ii mgii 600 robot/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
microgrid ii mgii 600 robot - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd microgrid compact
Microgrid Compact, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microgrid compact/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
microgrid compact - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd microgrid ii microarrayer
Microgrid Ii Microarrayer, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microgrid ii microarrayer/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
microgrid ii microarrayer - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd quill pins 2,500
Quill Pins 2,500, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/quill pins 2,500/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
quill pins 2,500 - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd microgrid pro arrayer
Microgrid Pro Arrayer, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microgrid pro arrayer/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
microgrid pro arrayer - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd microgrid tas arrayer
Microgrid Tas Arrayer, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microgrid tas arrayer/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
microgrid tas arrayer - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd solid-pin tool
Solid Pin Tool, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/solid-pin tool/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
solid-pin tool - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd microgrid ii/microspot 10 k pins
A: Coefficient of variation (CV) in probe signal intensities on cDNA microarrays . printed with (a) BioRobotics <t>Microgrid</t> II equipped with <t>MicroSpot</t> 10 K pins, (b) QArrayMini equipped with Telechem ChipMaker Pins, and (c) Molecular Dynamics GenIII spotter. The microarray meter probes were printed from stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. B: Signal dynamic range analysis (cDNA microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes (2, 20 and 200 ng/μl) was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. C: Coefficient of variation (CV) in probe signal intensities on oligonucleotide microarrays printed with (a) Molecular Dynamics GenIII spotter and (b) QArrayMini equipped with Telechem ChipMaker Pins. The microarray meter probes were printed from oligonucleotide stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. D: Signal dynamic range analysis (oligonucleotide microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. For the CV analysis presented in A and C , each robot's 12 pins printed 7 probes at the three different dilutions as 8 replicate spots on a slide. The mean values of the variation observed with each probe across all pins are represented as bars. The error bars denote one standard deviation. Data are plotted on a logarithmic scale in C and D . Each data point represents the mean of 96 measurements, (each of the 12 pins printed 8 replicate spots per probe per slide).
Microgrid Ii/Microspot 10 K Pins, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microgrid ii/microspot 10 k pins/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
microgrid ii/microspot 10 k pins - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Thermo Fisher microgrid-ii arrayer
A: Coefficient of variation (CV) in probe signal intensities on cDNA microarrays . printed with (a) BioRobotics <t>Microgrid</t> II equipped with <t>MicroSpot</t> 10 K pins, (b) QArrayMini equipped with Telechem ChipMaker Pins, and (c) Molecular Dynamics GenIII spotter. The microarray meter probes were printed from stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. B: Signal dynamic range analysis (cDNA microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes (2, 20 and 200 ng/μl) was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. C: Coefficient of variation (CV) in probe signal intensities on oligonucleotide microarrays printed with (a) Molecular Dynamics GenIII spotter and (b) QArrayMini equipped with Telechem ChipMaker Pins. The microarray meter probes were printed from oligonucleotide stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. D: Signal dynamic range analysis (oligonucleotide microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. For the CV analysis presented in A and C , each robot's 12 pins printed 7 probes at the three different dilutions as 8 replicate spots on a slide. The mean values of the variation observed with each probe across all pins are represented as bars. The error bars denote one standard deviation. Data are plotted on a logarithmic scale in C and D . Each data point represents the mean of 96 measurements, (each of the 12 pins printed 8 replicate spots per probe per slide).
Microgrid Ii Arrayer, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microgrid-ii arrayer/product/Thermo Fisher
Average 90 stars, based on 1 article reviews
microgrid-ii arrayer - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
BioRobotics Ltd microgrid robot
A: Coefficient of variation (CV) in probe signal intensities on cDNA microarrays . printed with (a) BioRobotics <t>Microgrid</t> II equipped with <t>MicroSpot</t> 10 K pins, (b) QArrayMini equipped with Telechem ChipMaker Pins, and (c) Molecular Dynamics GenIII spotter. The microarray meter probes were printed from stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. B: Signal dynamic range analysis (cDNA microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes (2, 20 and 200 ng/μl) was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. C: Coefficient of variation (CV) in probe signal intensities on oligonucleotide microarrays printed with (a) Molecular Dynamics GenIII spotter and (b) QArrayMini equipped with Telechem ChipMaker Pins. The microarray meter probes were printed from oligonucleotide stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. D: Signal dynamic range analysis (oligonucleotide microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. For the CV analysis presented in A and C , each robot's 12 pins printed 7 probes at the three different dilutions as 8 replicate spots on a slide. The mean values of the variation observed with each probe across all pins are represented as bars. The error bars denote one standard deviation. Data are plotted on a logarithmic scale in C and D . Each data point represents the mean of 96 measurements, (each of the 12 pins printed 8 replicate spots per probe per slide).
Microgrid Robot, supplied by BioRobotics Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microgrid robot/product/BioRobotics Ltd
Average 90 stars, based on 1 article reviews
microgrid robot - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

Image Search Results


A: Coefficient of variation (CV) in probe signal intensities on cDNA microarrays . printed with (a) BioRobotics Microgrid II equipped with MicroSpot 10 K pins, (b) QArrayMini equipped with Telechem ChipMaker Pins, and (c) Molecular Dynamics GenIII spotter. The microarray meter probes were printed from stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. B: Signal dynamic range analysis (cDNA microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes (2, 20 and 200 ng/μl) was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. C: Coefficient of variation (CV) in probe signal intensities on oligonucleotide microarrays printed with (a) Molecular Dynamics GenIII spotter and (b) QArrayMini equipped with Telechem ChipMaker Pins. The microarray meter probes were printed from oligonucleotide stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. D: Signal dynamic range analysis (oligonucleotide microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. For the CV analysis presented in A and C , each robot's 12 pins printed 7 probes at the three different dilutions as 8 replicate spots on a slide. The mean values of the variation observed with each probe across all pins are represented as bars. The error bars denote one standard deviation. Data are plotted on a logarithmic scale in C and D . Each data point represents the mean of 96 measurements, (each of the 12 pins printed 8 replicate spots per probe per slide).

Journal: BMC Research Notes

Article Title: Development and application of a microarray meter tool to optimize microarray experiments

doi: 10.1186/1756-0500-1-45

Figure Lengend Snippet: A: Coefficient of variation (CV) in probe signal intensities on cDNA microarrays . printed with (a) BioRobotics Microgrid II equipped with MicroSpot 10 K pins, (b) QArrayMini equipped with Telechem ChipMaker Pins, and (c) Molecular Dynamics GenIII spotter. The microarray meter probes were printed from stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. B: Signal dynamic range analysis (cDNA microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes (2, 20 and 200 ng/μl) was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. C: Coefficient of variation (CV) in probe signal intensities on oligonucleotide microarrays printed with (a) Molecular Dynamics GenIII spotter and (b) QArrayMini equipped with Telechem ChipMaker Pins. The microarray meter probes were printed from oligonucleotide stocks at 200, 20 and 2 ng/μl as described in the text with every capillary pin. D: Signal dynamic range analysis (oligonucleotide microarrays) . The signal intensities derived from hybridization of Cy5 labeled dynamic range spikes to increasing concentrations of complementary array probes was determined and plotted against the abundance of a particular sequence (expressed as an arbitrary copy number) in the hybridization reaction. For the CV analysis presented in A and C , each robot's 12 pins printed 7 probes at the three different dilutions as 8 replicate spots on a slide. The mean values of the variation observed with each probe across all pins are represented as bars. The error bars denote one standard deviation. Data are plotted on a logarithmic scale in C and D . Each data point represents the mean of 96 measurements, (each of the 12 pins printed 8 replicate spots per probe per slide).

Article Snippet: The CV for each pin across all 7 probes at each dilution range was examined and values were determined to be lowest for the Molecular Dynamics GenIII spotter/GenIII pins (mean, 4.8%), followed by the BioRobotics MicroGrid II/MicroSpot 10 K pins (mean, 7.1%) and the QArrayMini/ChipMaker pins (mean, 11.8%).

Techniques: Microarray, Derivative Assay, Hybridization, Labeling, Sequencing, Standard Deviation